TM 5-2420-224-20-2
FRONT LOADER/FORKLIFT CONTROL VALVE CONTROLS
REPLACEMENT AND ADJUSTMENT (CONT)
16. REMOVE four CLEVISES (3
17. REMOVE two rods (33) and
Procedure
and 15) and four jam nuts (32) from two rods (33).
lever BRACKET (7) from seal assembly seal (34).
NOTE
is the same for both vehicles except as noted.
1.
2.
3.
INSTALL two rods (1) and lever BRACKET (2) in seal assembly seal (3).
INSTALL four jam nuts (4) and four CLEVISES (5 and 6) on two rods (1).
MEASURE DISTANCE between pin hole center lines of two clevises (5 and 6) on each rod (1).
Distance should be 7 in. (178 mm).
If distance is NOT CORRECT, ROTATE each CLEVIS IN or
OUT, EQUALLY, until correct distance is achieved. TIGHTEN four jam NUTS (4) against four clevises
(5 and 6).
4-534