TM
11-5835-243-34/EE641-AA-MMI-010/E154
MTT/TO
31S3-4-110-1
Section Ill. TROUBLESHOOTING
through A5. Use the circuit card schematic
3-7. Introduction
diagrams, signal interconnecting list, and in-
This section contains the direct support fault
isolation procedures required to identify and correct
through FO-11 for signal tracing. In addition,
a tape transport or magnetic tape cartridge
malfunction. Fault isolation by direct support
maintenance personnel is based on a series of
operating voltages for the power amplifier circuit
functional tests using the Magnetic Tape Transport
card assembly A9.
Test Set TS-4002/UYH-5 (hereafter called the
exerciser). Some of the tests also use the Magnetic
3-9. Tape Transport Test Setup
Tape Test Cartridge TW-433/UYH-5 (hereafter
a. Connect tape transport to exerciser shown in
called the skew tape cartridge), while others require
only a standard tape cartridge.
b. Install a standard tape cartridge in the tape
3-8. Fault Isolation
transport and lock in place. Be sure write protect
detent is not in PROT position.
Isolation to a replaceable component is ac-
c. Refer to TM 11-6625-3024-14 for exerciser
complished by using the troubleshooting charts
operating instructions. Set exerciser controls as
follows:
POWER ON/OFF
These tests are arranged in a logical order of func-
SYSTEM
On
tions and must be performed in the sequence in
Depress PROCESSOR
Verify STOP indi-
which they appear. If the tape transport or cartridge
RESET
cater is ON.
fails a test, stop testing immediately and refer to the
(located on connector
If not, depress
appropriate troubleshooting chart for the repair
panel)
RESET again.
procedure. When the repair has been accomplished,
SELECT 1
On
repeat the entire test to verify the repair. In some
POWER ON/OFF
On
cases it may be necessary to trace signals with an
TRANSPORT
An extender card is provided in the IL Accessories
Set for accessing the test points on circuit cards Al
3-2