TM 11-5895-1412-12&Po Set FCTN to LD.o Press once,<CLR>, enter numbers for new days (last twodigits of Julian date) and press <Sto/ENT>.o Presstwice,<CLR>, enter numbers for new hours and minutesand press <Sto/ENT>.When <Sto/ENT> is pressed, seconds are reset to 00and the clock starts.CLEARING A SINGLE FH SETNOTE: You cannot clear the channel you are operating on.a.Set rt controls: FCTN to LD and MODE to FH.b. To clear hopset, press <CLR> and <CHANNEL/NUMBER/(1-6).c.To clear lockout set, press <CLR>, <L/9>, and <NUMBER/(1st DIGIT OF SET)>.d. Set rt switches to normal positions.I-14