TM 11-5895-1412-12&P
o Set FCTN to LD.
o Press
once,
<CLR>, enter numbers for new days (last two
digits of Julian date) and press <Sto/ENT>.
o Press
twice,<CLR>, enter numbers for new hours and minutes
and press <Sto/ENT>.
When <Sto/ENT> is pressed, seconds are reset to 00
and the clock starts.
CLEARING A SINGLE FH SET
NOTE: You cannot clear the channel you are operating on.
a.
Set rt controls: FCTN to LD and MODE to FH.
b. To clear hopset, press <CLR> and <CHANNEL/NUMBER/(1-6).
c.
To clear lockout set, press <CLR>, <L/9>, and <NUMBER/(1st DIGIT OF SET)>.
d. Set rt switches to normal positions.