TM 11-5895-1412-12&PTRANSEC VARIABLE LOADING (LOCAL FILL)Only one TRANSEC variable is needed in your rt. It must be stored in the PM(permanent memory).A second TRANSEC variable may be loaded into HM (holdingmemory) and stored for use at a later time.The NCS may also remotelytransmit the TRANSEC variable to your rt (refer to TM 11-5820-890-10-3).a.Set rt FCTN to Z-A (do NOT do this step if there are presets in the rtthat you want to save). Watch display. It must show “Good”.b. Set rt FCTN to TST.Watch display.It must show “Good” at the end oftest.c.Set ECCM fill device function switch to OFF; then connect fill cable to rtconnector AUD/FILL and to fill device connector J1.d. Set rt controls:FCTN to LD/V.MODE to FH, and CHAN to MAN (or 1-6).Display shows “FILLt”.e.Set ECCM fill device select switch to T1 or T2 (depending on whichvariable you wish to load).f. Set ECCM fill device function to ON.g.Press rt h. After TRANSEC variable is loaded, set ECCM fill device function switch toOFF before disconnecting fill cable.I-11