TM 11-5895-1412-12&P
TRANSEC VARIABLE LOADING (LOCAL FILL)
Only one TRANSEC variable is needed in your rt. It must be stored in the PM
(permanent memory).
A second TRANSEC variable may be loaded into HM (holding
memory) and stored for use at a later time.
The NCS may also remotely
transmit the TRANSEC variable to your rt (refer to TM 11-5820-890-10-3).
a.
Set rt FCTN to Z-A (do NOT do this step if there are presets in the rt
that you want to save). Watch display. It must show Good.
b. Set rt FCTN to TST.
Watch display.
It must show Good at the end of
test.
c.
Set ECCM fill device function switch to OFF; then connect fill cable to rt
connector AUD/FILL and to fill device connector J1.
d. Set rt controls:
FCTN to LD/V.
MODE to FH, and CHAN to MAN (or 1-6).
Display shows FILLt.
e.
Set ECCM fill device select switch to T1 or T2 (depending on which
variable you wish to load).
f. Set ECCM fill device function to ON.
g.
Press rt
h. After TRANSEC variable is loaded, set ECCM fill device function switch to
OFF before disconnecting fill cable.
I-11