TM 11-5805-424-15/NAVSHIPS 0967-220-9010/TO 31W2-2G-41
c. Procedure- Continued
Control settings
Step
No.
Test equipment
Equipment under test
Procedure
Performance standard
DD-205A
1
MX-7373/G: 510 cps.
MX-7374/G: 765 cps.
TRANSITION SELECT:
MX-7375/G: 680 cps.
SPACE
MX-7376/G: 1105 cps.
Left hand: ALL MARK
MX-7377/G: 1190 cps.
MX-7378/G: 1445 cps.
Right, hand: ALL,.
DISTORTION SELECT: AVG.
INPUT FILTER: OUT.
EXTERNAL: 37.5
1200
INPUT POLARITY: As required.
MX-7379/G: 1200 cps.
INPUT SELECT: POLAR LOW
MX-7380/G: 1785 cps.
LEVEL
MX-7381/G: 1870 cps.
BAUDS: As required.
MX-7382/G: 2125 cps.
Toggle switch: SYNCHRONOUS.
MX-7383/G: 2040 cpa.
RESET: AUTO.
MX-7384/G: 2465 cps.
MX-7385/G: 2550 cps.
350D
MX-7386/G: 2805 cps.
DB: 0.
d. Operate INPUT SELECT
d. Electronic Counter 5233L should in-
switch to SPACE.
dicate as follows for each MX-73
Electronic Counter 5tSSL
(*) /G ( 0.5 cps):
MX-7372/G: 595 cps.
MX-7373/G: 850 cps.
TIME-BASE-MULTIPLIER:
MX-7374/G: 935 cpa.
6
luS10 .
MX-7375/G: 1360 cps.
SAMPLE RATE: Midposition.
MX-7376/G: 1275 cps.
COM-SEP-CHECK: SEP.
MX-7377/G: 1530 cps.
DC VOLTS-AC VOLTS: AC
MX-7378/G: 1615 cps.
VOLTS X 100.
MX-7379/G: 2400 cps.
MX-7380/G: 1955 cps.
ME-86A/U
MX-7381/G: 2210 cps.
SELECTOR: DC.
RANGE: 10V.
7-4