TM 5-2420-224-20-2
SLAVE RECEPTACLE REPLACEMENT
This task covers:
a. Removal b. Installation
I N I T I A L S E T UP
Tools and Special Equipment:
Equipment Condition:
Tool Kit, SC 5180-90-CL-N26
Reference
Condition Description
Materials/Parts:
Page 2-24
Batteries Disconnected
Washer, Spring
Tension (2)
Nut, Lock (2)
R E M O V A L
1.
REMOVE two screws (1), two spring tension
washers (2), and COVER (3). DISCARD
spring tension WASHERS.
NOTE
Tag leads prior to removal to aid
In installation.
2.
DISCONNECT two LEADS (4) from slave
receptacle (5).
3.
REMOVE four nuts (6), four screws (7), and
slave RECEPTACLE (5).
4.
REMOVE two screws (8), two lock nuts (9),
and BRACKET (10). DISCARD lock NUTS.
I N S T A L L A T I ON
1.
INSTALL BRACKET (10), two screws (8), and
two new lock nuts (9).
2.
INSTALL slave RECEPTACLE (5), four screws
(7), and four nuts (6).
3.
CONNECT two LEADS (4) to slave receptacle
(5).
4.
INSTALL COVER (3), two new spring tension
washers (2), and two screws (1).
NOTE
Follow-on Maintenance:
Connect batteries (page 2-24).
4-172