TM 5-2420-224-20-2
LOW OIL PRESSURE AND HIGH WATER TEMPERATURE ALARM
REPLACEMENT
This task covers:
a. Removal b. Installation
INITIAL SETUP
Tools and Special Equipment:
General Safety Instructions:
Tool Kit, SC 5180-90-CL-N26
W A R N I N G
Remove or disconnect batteries
a n d t u r n v e h i c l e M A S T E R
disconnect switch OFF prior to
p e r f o r m i n g m a i n t e n a n c e i n
i m m e d i a t e b a t t e r y a r e a o r
working on electrical system.
S u c h d i s c o n n e c t i o n s p r e v e nt
electrical shock to personnel or
equipment.
1.
REMOVE five screws (1) and TOWER (2)
NOTE
Tag wires prior to disconnecting to
aid in connecting.
2.
CAREFULLY ROLL BACK rubber COVERS
(3) and DISCONNECT two WIRES (4).
3.
REMOVE two screws (5), two nuts (6) and
ALARM (7).
l N S T A L L A T I ON
1.
INSTALL ALARM (7), two screws (5), and two
nuts (6).
2.
CONNECT two WIRES (4) and CAREFULLY
ROLL rubber COVERS (3) BACK in place.
3.
INSTALL TOWER (2) and five screws (1).
4-170