TM 5-2420-224-20-2
AUXILIARY THROTTLE SWITCH REPLACEMENT
This task covers:
a. Removal b. Installation
I N I T I A L S E T U P
Applicable Configuration:
General Safety Instructions:
HMMH
Tools and Special Equipment:
Tool Kit, SC 5180-90-CL-N26
W A R N I N G
Remove or disconnect batteries
a n d t u r n v e h i c l e M A S T E R
disconnect switch OFF prior to
p e r f o r m i n g m a i n t e n a n c e in
i m m e d i a t e b a t t e r y a r e a or
working on electrical system.
S u c h d i s c o n n e c t i o n s p r e v e n t
electrical shock to personnel or
equipment.
1.
2.
3.
4.
REMOVE five screws (1) and
REMOVE two screws (3) and
control TOWER (2).
RPM SWITCH (4).
NOTE
Tag all wires prior to removal to aid in installation.
REMOVE two WIRES (5) from RPM SWITCH (4).
CAREFULLY ROLL BACK rubber COVERS (6) and REMOVE two WIRES (7), two screws (8), and low
oil pressure ALARM (9).
4-156