TM 11-5895-1412-12&P
LOCKOUT SET LOADING (LOCAL FILL)
Check the SOI for required lockout set(s).
a.
Make sure that the ECCM fill device is loaded.
o Check to see if the lockout set(s) have already been loaded in rt: Set
rt FCTN to SQ ON, rt MODE to FH, CHAN to channel where hopset is stored;
then press rt FREQ several times.
Watch display for lockout set
numbers.
b.
Set ECCM fill device function switch to OFF.
c.
Connect fill cable to rt connector AUD/FILL and to fill device connector
J1.
d.
Set rt controls:
FCTN to LD and MODE
e.
Make sure rt CHAN is not set to CUE.
f.
Set ECCM fill device select switch to
set.
g.
Set ECCM fill device function to ON.
h.
Press rt <LOAD/0>. A beep is heard
to FH.
position containing the lockout
i.
Press <STO>.
Display blinks and shows STO
L
followed by the first digit
of the lockout number.
o If additional lockout sets are to be loaded, repeat steps a thru i for
each.
j.
Set ECCM fill device function switch to OFF.
k.
Disconnect ECCM fill device from rt connectorAUD/FILL.
l.
Set rt switches as needed for normal operation.
HOPSET LOADING (LOCAL FILL).
Check the SOI for required lockout set(s).
a.
b.
c.
d.
e.
f.
g.
h.
i.
Make sure that the ECCM fill device is loaded.
Set ECCM fill device function switch to OFF.
Connect fill cable to rt connector AUD/FILL and to fill device connector
J1.
Set rt controls:
FCTN to LD and MODE to FH.
Make sure rt CHAN is not set to CUE.
Set ECCM fill device select switch to position containing the hopset.
Set ECCM fill device function to ON.
Press <LOAD/0>.
A beep is heard
Press <STO>.
Display blinks and shows STO_.
J-9