TM 5-2420-224-20-2
AIR CLEANER REPLACEMENT (CONT)
3.
REMOVE wing nut (6), washer seal (7), and
filter ELEMENT (8). DISCARD washer SEAL.
NOTE
Tag wires prior to disconnecting to
aid in connecting.
4.
DISCONNECT two WIRES and REMOVE
sender UNIT (9).
5.
DISCONNECT two HOSES (10 and 11).
6.
REMOVE two bolts (12) and two CLAMPS
(13).
7.
REMOVE 10 screws (14), 10 lock washers
(15), and BRACKET (16). DISCARD lock
WASHERS.
8.
REMOVE valve (17) and air CLEANER (18).
l N S T A L L A T I O N
1.
INSTALL air CLEANER (1) and valve (2).
2.
INSTALL BRACKET (3), 10 screws (4), and
10 new lock washers (5).
NOTE
When installing clamps, make sure
larger clamp is on the right.
3.
INSTALL two CLAMPS (6) and two bolts (7).
4.
CONNECT two HOSES (8 and 9).
5.
INSTALL sender UNIT (10) and CONNECT
two WIRES.
4-33