TM 5-2420-224-20-2
HYDRAULIC SUSPENSION LOCKOUT PUMP REPLACEMENT (CONT)
1.
REMOVE four bolts (1), two lock nuts (2), six
washers (3), and COVER (4). DISCARD lock
NUTS.
2.
3.
C A U T I O N
Cap or plug all ports and ends
of hoses and tubes to prevent
contamination of hydraulic oil.
Failure to do so may result in
damage to equipment.
NOTE
Tag lines prior to disconnecting to
aid in connecting.
REMOVE two fluid passage BOLTS (5) and
four seal rings (6) and DISCONNECT two
hydraulic HOSES (7). INSTALL CAPS or
PLUGS. DISCARD seal RINGS.
REMOVE fluid passage BOLT (8) and two
seal rings (9) and DISCONNECT vent HOSE
(10). DISCARD seal RINGS.
4-512