TM 5-2420-224-20-2
POLARITY BREAKER AND SUPPRESSOR FILTER MOUNTING
BRACKET REPLACEMENT
This task covers: a. Removal b. Installation
INITIAL SETUP
Tools and Special Equipment:
Equipment Condition:
TooI Kit, SC 5180-90-CL-N26
Reference
Condition Description
Materials/Parts:
Page 4-121
Polarity Breaker Removed
Washer, Lock (2)
Page 4-235
Suppressor Filters
Removed
1.
2.
3.
NOTE
Tag wires prior to removal to aid
in installation.
REMOVE two WIRES (1) and CONNECTOR
(2) from bracket (3).
REMOVE two socket head screws (4), two
lock washers (5), washer (6), and BRACKET
( 3 ) f r o m e n g i n e ( 7 ) . D I S C A R D l o ck
WASHERS.
REMOVE GROMMET (8) from bracket (3).
1.
INSTALL GROMMET (8) in bracket (3).
2.
INSTALL BRACKET (3), washer (6), two new
lock washers (5), and two socket head screws
(4) on engine (7).
3.
INSTALL CONNECTOR (2) and two WIRES
(1) in bracket (3).
NOTE
Follow-on Maintenance:
Install suppressor filters (page
4-235).
Install polarity breaker (page
4-121).
4-120
REMOVAL