TM 11-7440-232-12/ NAVELEX 0967-LP-275-5010
Table 5-1. ORGANIZATIONAL PREVENTIVE MAINTENANCE CHECKS AND
SERVICES WEEKLY SCHEDULE
Item No.
Item to be
Procedures
inspected
1
Controls, screws,
Inspect all controls and mechanical assemblies for
bolts
loose or missing knobs, screws, bolts, and nuts.
2
Connectors fuse
holder fuses
including the fuses, fuse holder, for looseness and
damage.
3
Modules
Visually inspect exterior and component side of
modules for scorched parts or broken connections or
blown fuses.
4
Finish
Inspect case (or chassis) for damage, missing parts,
and condition of finish and panel lettering. Painted
external surfaces do not show bare metal. Panel
5
Transmit Branch
and TRANS MODE switch to PATT position. On
limiter discriminator, set REC MODE switch to NORM
position.
Set POWER switch on power supply to ON position;
Allow a 30-minute warm-up of digital data modem.
Connect a VTVM between GRD (TP4) and Line (TP3)
level indication. POWER lamp lights. The VTVM will
indicate between -10 and +6 dbm (unless otherwise
specified) and will provide a signal at the distant
terminal that will be between -30 and +10 dbm (as
measured at limiter input).
NOTE
On telephone company lines, the transmit level is usually -8 dbm. On
private communication facilities, the level is generally 0 dbm to open
wire or cable lines, or 10 dbm below test tone level to carrier or
5-7